| NFPA 2112 STANDARD ON FLAME RESISTANCE GARMENTS FOR PROTECTION OF INDUSTRIAL PERSONEL AGAINTS FLASH FIRE | |
| PERFORMANCE REQUIREMENTS | |
| | Thermal Protective Performance (TPP): Shall be have a “spaced” TPP rating of not less than 25 J/cm2 (6.0 cal/cm2) and a “contact” TPP rating of not less than 12,6 J/cm2 (3.0 cal/cm2) |
| ASTM D6413 | Flame resistance flame (vertical test) Fabric and reflective striping utilized in the construction of flame-resistance garments shall have a char length of not more than 100 mm ( 4 in) and an afterflame of not more than 2 seconds, and shall not melt and drip. |
| AATCC 135 | Heat and thermal shrinkage resistance test. Fabrics utilized in the construction of flame-resistance garments, excluding manufacturers’ labels, shall be individually tested for thermal shrinkage resistance and shall not shrink more than 10% in any direction. |
| ASTM F 1930 | Manikin Test. Specimen garments shall be tested for overall flash fire exposure, as a qualification test for the material and shall have and average predicted body burn rating of not more than 50. |